Mechanical ventilation allows for a continuous and sufficient replacement of the air volumes in enclosed spaces through stale air extraction and fresh air intake. This helps to reduce the presence of viral bioaerosols that might otherwise remain suspended in the air and spread by air.
Flow 800
Forced ventilation system with air filtration and heat recovery for environments such as classrooms, offices, laboratories and small public spaces.
Decentralised ventilation ideal for school, offices and large spaces
High-performing and discreet, the Helty Flow800 HRV system introduces a refreshed design while expanding the Community family with new versions. These enhancements best cater to the needs of designers and clients; engineered to ensure optimal air exchange in individual, spacious rooms, Flow800 offers adjustable air flow rates ranging from 300 to 800 m3 per hour. This versatility makes it a perfect solution for ventilating classrooms and community environments.
Prezzo su richiesta
The new Helty Flow800 represents the ideal decentralized HRV for ventilating larger spaces such as schools, nurseries, and workplaces with prolonged occupancy. In these settings, a continuous supply of fresh and filtered outdoor air is essential for enhancing indoor environmental conditions.
HRV for schools with no need for ductwork design
Added to the HRV unit itself, which is designed for ceiling-mounted installations, the Flow800 range introduces new variations: Flow800 Steel, integrating the HRV into a white-painted steel cover for visible installations, suitable for both ceiling and wall placement; Flow800 Silent, completed with a white wooden cover for ceiling installations that minimized aesthetic and acoustic impact of the HRV; FlowM800, where the ventilation unit is completely concealed, blending into a white cabinet that seamlessly integrates into spaces, offering easy access for inspections and filter changes.
Cabinet-style HRV simplifying design and management
The option to house the heat recovery mechanical ventilation unit within a cabinet makes the Helty FlowM800 a practical and versatile choice for upgrading classrooms, nurseries, and offices. The machine requires no complex ductwork design and can be installed quickly with two 250 mm cores in the perimeter masonry. FlowM800 is also available with air duct outlets on either the right or left side, offering maximum design flexibility in system integration and simplified maintenance through filters accessible by a side inspection door.
Air exchange and sanitization for assured indoor well-being
Flow800 stands for high air exchange rates without compromising aesthetics and acoustics. Air flow rates can be adjusted in six settings, from 300 m3/h (night mode) to 800 m3/h (maximum speed in hyper-ventilation mode), using the intuitive Helty control panel. The dual G3+F9 filters capture 90% of PM10 and 80% of PM2.5 particles, delivering purified and oxygenated air indoors while preventing smog and pollen from entering. Opting for versions equipped with bipolar ion sanitization devices further reduces the risks of airborne distribution of microbial, bacterial, and viral contaminants, leading to energy savings.
Silence, efficiency, and energy savings
Thanks to the enthalpy heat exchanger, the Helty Flow800 HRV unit ensures an 80% thermal exchange efficiency, exchanging air without compromising the building’s energy performance. The minimum sound pressure of 21.5 dB (in Silent configuration) and the option to choose the Pure version, featuring a hygrometric sensor, CO2, and VOC sensors, transform Flow800 into a discreet and intelligent HRV system capable of autonomously regulating air exchange, ensuring maximum comfort in every environment.
Dati tecnici
| Caratteristiche | U.M. | Valore | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Airflow | m3/h | 300/350/500/600/700/800 | ||||||||||||||||||||||||||||||
| Airflow adjustment | night + 4 stages + hypervent. | |||||||||||||||||||||||||||||||
| Power consumption (1) | W | 22/26/46/61/90/138 | ||||||||||||||||||||||||||||||
| Supply voltage | V AC | 230 | ||||||||||||||||||||||||||||||
| Max. current consumption (2) | A | 0,7 | ||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||
Download
Are you a reseller?
Are you interested in offering your customers our products? Find out how we can work together
Become a reseller
Frequently asked questions
Replacing indoor air with fresh air from outdoors that is continuously filtered and cleaned eliminates the problems associated with stale air, prevents the onset of mould and reduces the risk of exposure to dangerous indoor pollutants.
Natural ventilation through manual window opening is impractical, difficult to manage and energy-consuming. A mechanical ventilation system allows you to fully automate stale air removal and fresh air intake, delivering continuous indoor air purification and greater energy efficiency.